🌐 www.dgkinz.comShenzhen Kinz Optoelectric Technology Co., Ltd.
FiberKinZKINZ OPTOELECTRIC
SMI · Small Multimedia Interface · IEC 61754-21 · POF-Specific Duplex

SMI Connectors

The duplex interface dedicated to plastic optical fibre. International standard IEC 61754-21:2005, whose title explicitly states for plastic optical fibre — this is not a miniaturised silica-fibre interface, but a separate system that grew up within the POF era. Two defining numbers: 2.5 mm ferrule, 5.0 mm duplex pitch.

📐 No product photograph of an SMI connector is available on this page. Every image currently in our library failed visual confirmation as an SMI interface, so to avoid mislabelling, all structures are shown as dimensioned diagrams. The 5.0 mm pitch and 2.5 mm ferrule diameter shown are taken from IEC 61754-21. Photographs can be provided separately on request.

What SMI Is

SMI stands for Small Multimedia Interface. It was developed by SMAT (SMI connector Mutual AssociaTion), an industry consortium prepared by seven Japanese companies from June 1999, which had 28 participating companies including overseas members by its public announcement in September 2000.

The international standard is IEC 61754-21, published on 24 March 2005, and its title is explicit: Type SMI connector family for plastic optical fibre. Note that final qualifier — this interface family was specified for plastic fibre from the outset.

ItemDetail
Full nameSmall Multimedia Interface
StandardIEC 61754-21:2005 (European adoption EN 61754-21:2005)
Published2005-03-24
MediumPlastic optical fibre (POF), not silica
Promoting bodySMAT (SMI connector Mutual AssociaTion)
ConfigurationDuplex plug connector
Key dimensions5.0 mm ferrule pitch · 2.5 mm ferrule diameter

Why POF Needed Its Own Interface Standard

The silica-fibre connector families (SC, LC, FC, ST) solve one problem: aligning a 9 μm or 50 μm core to within a few micrometres. POF faces an entirely different situation — the core is 1 mm, far coarser, and alignment is not the difficulty at all.

POF's difficulties lie elsewhere:

Cannot be polished

PMMA is soft. Polishing smears the material across the end face and makes it progressively worse. Silica must be polished; POF must not be. This is a materials boundary.

Cost must stay minimal

The whole value of POF is that it is cheap. Fit a precision ceramic-ferrule interface and the connector costs several times the fibre, and the business case collapses.

Duplex, and small

In information appliances and set-top boxes, one cable must carry both directions and fit into a small enclosure. Two separate simplex connectors take too much space.

Field-terminable

Consumer electronics and industrial installation sites have no polishing machine or curing oven. It must be no-epoxy, no-polish: cut with a tool and go.

Those four constraints together produce the SMI form: injection-moulded plastic housing, integrated duplex, ferrules located by mould precision, no polishing at termination.

Structure: Duplex, 5.0 mm Pitch, 2.5 mm Ferrules

SMI plug end face (front view) 1mm core 1mm core 5.0 mm Ø2.5 ferrule Integrated duplex · moulded housing · located by mould precision Two latching types (defined by IEC 61754-21) Push-pull push-pull latching Latch · tactile feedback · pull-out resistant Friction-lock friction-lock Interference fit · low force · weaker vibration resistance ⚠ The two plugs look similar but are NOT interchangeable Confirm which type the equipment receptacle was built for
Fig. 1 · SMI plug end face structure and the two latching types (dimensions per IEC 61754-21, structural diagram)

Two numbers matter:

The standard also defines two plug types: push-pull latching and friction-lock. Push-pull has a definite latch, gives tactile feedback when seated, and resists pull-out; friction-lock relies on housing interference fit, with lower insertion force and a simpler structure but weaker resistance to vibration and pull. The two plugs look similar but are not interchangeable — confirm which type the equipment receptacle was built for before ordering.

Density Comparison with SC and LC

Ferrule centre spacing of three duplex interfaces (same scale) SC duplex (silica) 12.5 mm 2.5 mm ferrule · ceramic sleeve precision alignment LC duplex (silica) 6.25 mm 1.25 mm ferrule · precision ceramic alignment SMI (POF only) 5.0 mm 2.5 mm ferrule · moulded housing location The counter-intuitive point SMI's ferrule is twice LC's (2.5 vs 1.25), yet its duplex pitch is smaller (5.0 vs 6.25). Because POF needs no precision alignment.
Fig. 2 · Ferrule centre spacing of SC duplex, LC duplex and SMI (to scale)
InterfaceFerrule diameterDuplex pitchMediumAlignment method
SC duplex2.5 mm~12.5 mmSilica fibreCeramic sleeve precision alignment
LC duplex1.25 mm~6.25 mmSilica fibreCeramic sleeve precision alignment
SMI2.5 mm5.0 mmPOF plastic fibreMoulded housing, mould precision

The most notable row here is SMI. Its ferrule diameter is twice that of LC, yet its duplex pitch is smaller than LC's. Under silica-fibre logic that would be impossible — a larger ferrule requires more alignment space. But POF's 1 mm core is inherently forgiving, and a moulded housing located by mould precision is sufficient without the whole precision ceramic sleeve arrangement.

In other words: SMI is small not because of precision, but because it does not need precision. Understand that and you understand why the interface is shaped this way, and why its cost can be driven down.

The Two Latching Types

TypePrincipleAdvantageTrade-off
Push-pull latchingLatch structure: push to lock, pull to releaseTactile feedback when seated, resists pull-outMore complex, slightly higher cost
Friction-lockHousing interference fit, held by frictionLow insertion force, simple, low costWeaker resistance to vibration and pull

The two plugs look similar but are not interchangeable. This is the most common purchasing error — they look alike in a photo, the order is placed, and the parts will not seat in the equipment receptacle. Confirm which type the equipment originally used; the fastest route is a straight-on photograph of the receptacle.

The Four Interfaces Defined by the Standard

InterfaceContentNote
Interface 1Plug connector interface (push-pull)Defines plug end-face dimensions and tolerances
Interface 2Plug connector interface (friction-lock)Same, with a different latching mechanism
Interface 3Receptacle interfaceThe fixed end on the equipment panel
Interface 4Adapter interfaceFor mating two plugs together

The standard fixes the mechanical datums, dimensional tolerances and intermateability rules so that plugs, receptacles and adapters from different suppliers are mechanically interchangeable. That is also why an enquiry for an "SMI connector" should state whether it is a plug, a receptacle or an adapter — the three have different interface definitions, and the wrong one produces the wrong part.

Field Termination: No Polishing, No Epoxy

This is SMI's most practical advantage over silica-fibre interfaces. The matching process is no-epoxy, no-polish — no epoxy cure, no polishing, just cut with a dedicated tool and secure.

StepSilica-fibre interfaceSMI (POF)
End-face treatmentMust be polished (PC / UPC / APC)Not polished, cut with a dedicated tool
FixingEpoxy cure, requires waitingNo epoxy, mechanical clamping
Field toolingPolishing machine, curing oven, inspection scopeCleaver plus crimp tool
Time per endMinutes, plus cure timeTens of seconds
WhySilica is hard, can be polished sub-micronPMMA is soft, polishing smears it

The reason is simple: PMMA is soft, and polishing smears material across the end face, making it worse. A POF end face can only be cut, never polished. This is not a process choice, it follows from the material. Conversely, if someone supplies you a POF end face that has been polished, that is a strong indication the end-face quality is suspect.

Applications

ApplicationDetailStatus
IEEE 1394b (FireWire)SMI was adopted by IEEE as a medium-distance data link interfaceIEEE 1394 has left the market
Set-top boxes / IPTVAn early target application, consistent with the information-appliance positioningMoved to HDMI and wireless
In-equipment data linksHigh-speed board-to-board inside an enclosureStill used in some installed equipment
Industrial POF data portsCommon POF data interface on German-made equipmentThe main current source of demand
Ethernet 10/100 short linksShort-reach Ethernet over POFStill used in specific installations

To be clear: SMI's consumer demand has essentially disappeared. It was born when the information-appliance concept was at its peak; IEEE 1394 later left the market and set-top boxes moved to HDMI and wireless. But industrial equipment still uses it — POF data ports on earlier German-made machines are SMI receptacles, and those machines are still running on production lines, so replacements must match the original interface.

In practice, almost everyone asking for SMI today needs equipment repair replacement or production-line spares, not a new design selection. For new projects, SC or LC is usually the simpler route.

SC–SMI Hybrid Patch Cords

SC on one end and SMI on the other, used where the equipment port and the cabling port have different interfaces. This is a typical custom item in POF systems:

Common combinationUseInformation required
SC – SMISMI receptacle on the equipment side, SC on the cabling sideBoth connector types, fibre specification, length
SMI – SMIDirect connection between two SMI devicesWhether both latching types match
SC – SCConventional POF linkSinglemode/multimode, end-face polish

When ordering, state the latching type at each end separately in addition to the length. Within the same SMI interface, push-pull and friction-lock plugs are not interchangeable, and mixing them means the parts will not fit.

Key Specifications

ItemTypical value
StandardIEC 61754-21:2005
ConfigurationDuplex plug connector
Ferrule diameter2.5 mm
Duplex centre spacing5.0 mm
FibrePOF, commonly 980 / 1000 μm
LatchingPush-pull / friction-lock
TerminationNo epoxy, no polish, dedicated cleaver
Typical link capability250 Mbps over 50 m (980/1000 μm POF)

Rate and distance are typical values from public product documentation. Each project must be calculated from the actual fibre specification and link budget. POF has a limited bandwidth-distance product; higher data rates reduce reachable distance.

Related Products

ItemDescriptionPage
POF plastic optical fibreThe physical medium for SMI links, commonly 980/1000 μmView
SC / FC / LC telecom connectorsSilica-fibre interfaces, often combined with SMI in hybrid cordsView
MOST automotive fiber connectorsIn-vehicle POF bus interfaceView
Specialty fiber patch cordsSC–SMI and other hybrid cords made to orderView
FAQ

Frequently Asked Questions

What does SMI stand for?

SMI stands for Small Multimedia Interface. It was developed by SMAT (SMI connector Mutual AssociaTion), an industry consortium prepared by seven Japanese companies from June 1999, which had 28 participating companies including overseas members by the time of its public announcement in September 2000. The international standard is IEC 61754-21, published on 24 March 2005, whose title explicitly states for plastic optical fibre.

What is the essential difference between SMI and SC?

The essential difference is the medium. SC is a silica fibre interface; SMI is dedicated to plastic optical fibre. Structurally both use 2.5 mm ferrules, but the duplex SC version has a ferrule centre spacing of about 12.5 mm while SMI is only 5.0 mm, more than double the density. SMI also uses an injection-moulded housing located by mould precision, whereas SC relies on a ceramic sleeve for alignment, so the manufacturing routes are entirely different.

Why does SMI have a larger ferrule than LC but a smaller duplex pitch?

Because POF has a 1 mm core, the ferrule must be 2.5 mm to accommodate it, which cannot compete with LC's 1.25 mm. But POF does not need LC-grade precision alignment: a 1 mm core is inherently forgiving, and an injection-moulded plastic housing located by mould precision is sufficient without a precision ceramic sleeve. That allows the two ferrules to sit very close, with a 5.0 mm centre spacing. SMI is small not because of precision, but because it does not need precision.

How many latching types does SMI define?

The standard defines two plug types: push-pull latching and friction-lock. Push-pull has a definite latch structure with tactile feedback when fully seated and resists pull-out; friction-lock relies on housing interference fit, giving low insertion force and a simpler structure but weaker resistance to vibration and pull. Selection must match whatever the equipment receptacle was originally built for; the two plugs look similar but are not interchangeable.

Is SMI still used today?

Yes, but the application has shifted. It was originally designed for information appliances, was adopted by IEEE 1394b in the 2000s as a medium-distance data link, and was used in set-top boxes and IPTV. IEEE 1394 later left the market and set-top boxes moved to HDMI and wireless, so consumer demand has essentially disappeared. Industrial equipment still uses it, particularly POF data ports on earlier German-made equipment, where the installed receptacle is SMI and only the original interface will fit.

Does SMI field termination require polishing?

No, and that is one of the design goals. The standard termination process is no-epoxy, no-polish: cut with a dedicated tool and secure mechanically. The reason is direct: POF is PMMA, a soft material, and polishing smears it across the end face, making it progressively worse. Silica fibre must be polished; POF must not be. That is the boundary between the two materials.

What is an SC-to-SMI hybrid patch cord for?

One end SC and one end SMI, used where the equipment port and the cabling port have different interfaces. This is common in industrial equipment: the device side has an SMI receptacle, the cabling side has an SC receptacle, and a transition cord is needed between them. It is a typical custom item in POF systems, with both length and both connector ends confirmed against the actual installation.

How fast and how far can SMI transmit?

According to publicly available Molex SMI interconnect product documentation, POF links can reach 250 Mbps over 50 metres, specified for 980/1000 um POF. Note that POF has a limited bandwidth-distance product, so the higher the data rate the shorter the reachable distance. Each project must be calculated from the actual fibre specification and link budget rather than applying the maximum figure directly.

Need an SMI connector or SC–SMI hybrid cord?

Please provide: equipment brand and model, a straight-on photo of the equipment receptacle, latching type (push-pull / friction-lock), fibre specification (e.g. 980/1000 μm) and required length. A receptacle photo is the fastest route — we can compare the structure directly and avoid mixing up the push-pull and friction-lock plugs.

Get a Quote