Threaded coupling, air gap construction, replaceable ferrule. The workhorse interface for medical laser, spectroscopy, sensing and high power delivery. Its strength and its weakness come from the same structural feature: the air gap between end faces.
SMA stands for SubMiniature version A, originally developed by Bendix and now a general threaded interface in both RF and fiber optics. The 905 refers to the thread: 5/16-24 UNF, 0.3125 inch outside diameter with 24 threads per inch, unified fine thread.
Here is a point that trips up purchasing: 905 only fixes the thread. A request for "SMA905" says how the housing screws on and nothing else. Ferrule bore, ferrule material and end face form are all still open, and those three decide whether it works. A request that says only "SMA905" forces the supplier to guess or quote the most common configuration, and that is how wrong parts get ordered.
That gap produces two consequences, one good and one bad, and neither can be avoided:
With physical contact the two end faces press together, and at high power any contamination absorbs energy, heats rapidly and burns a pit into the end face. The air gap has no such contact interface, and an end cap can be added, which is why SMA905 became the default for high power and medical laser.
The glass to air interface produces Fresnel reflection, giving return loss around -20 dB while PC reaches -40 dB or better. This is structural, not a defect. Narrow linewidth lasers, interferometry and fiber optic gyroscopes are sensitive to return loss and should not use SMA905.
This is the most frequently made and most frequently overlooked error in SMA905 purchasing. The fiber passes into the ferrule bore, and the relationship between bore and fiber outside diameter directly determines centering accuracy:
| Ferrule bore | Fiber outside diameter | Typical use | Consequence of a mismatch |
|---|---|---|---|
| 126 μm | 125 μm cladding (singlemode / multimode) | Telecom, sensing | Bore too large means off center fiber, worse loss and consistency |
| 140 μm | 125 μm cladding with thin coating | Slim patch cords | Incompletely stripped coating prevents full insertion |
| 230 μm | 200/230 μm large core | Large core delivery | Looseness with 220 μm fiber |
| 440 μm | 400 μm core / 440 μm cladding | Medical, sensing | Excess clearance causes unstable coupling efficiency |
| 600 μm | 600 μm core / 630 μm cladding | Medical laser, lighting | Most common size, still verify the actual diameter |
| 1000 μm | 1000 μm core / 1035 μm cladding | High power, lithotripsy | Undersized bore chips the fiber end on insertion |
When requesting a quote, state both the fiber outside diameter and the coating diameter. Many wrong orders come from quoting only the core size: a 600 μm core fiber may be 600 μm bare, or 630 μm or 750 μm with coating, and each needs a different bore.
| Item | SMA905 | SMA906 |
|---|---|---|
| Centering | Fiber passes directly into the bore | Adds a shoulder ring to assist centering |
| Large core stability | Moderate | Better |
| Assembly difficulty | Lower | Higher |
| Cost | Lower | Slightly higher |
| Thread | 5/16-24 UNF | 5/16-24 UNF (identical) |
| Best for | Small core, short reach, cost sensitive | Large core, multimode, repeatability critical |
The threads are identical so either mates with the same receptacle, but internal centering differs. Rule of thumb: the thicker the fiber and the higher the consistency requirement, the more you should use SMA906. Fiber bundles and imaging bundles almost always use 906, because a bundle carries tens or hundreds of strands and any eccentricity is amplified into uneven transmission.
| Item | SMA905 | FC | LC |
|---|---|---|---|
| Locking | Threaded | Threaded with key | Small latch |
| End face contact | Air gap | Physical contact PC/APC | Physical contact PC/APC |
| Return loss | About -20 dB | -40 to -60 dB | -40 to -55 dB |
| High power capacity | Best | Moderate | Poor |
| Large core suitability | Best | Moderate | Poor |
| Replaceable ferrule | Yes | No | No |
| Typical use | Medical laser, spectroscopy, sensing, high power | Telecom, test instruments | Data centers, high density |
Selection order: power density first (high end face power means SMA905 with an end cap) → then return loss (a -40 dB requirement means FC/APC only) → then fiber size (above 200 μm essentially only the SMA family fits).
| Form | Method | Use | Notes |
|---|---|---|---|
| Flat polish | Fiber cleaved flat and polished | Multimode, large core, moderate power | Most common, simple and low cost |
| Spherical polish | End face ground to a slight dome | Where lower return loss is required | Limited benefit on SMA905 because of the air gap, do not over expect |
| End cap | Coreless silica rod spliced to the fiber end | High power, medical lithotripsy, industrial | Reduces power density by one to two orders of magnitude, the most effective protection |
The end cap deserves emphasis: the decision depends on power density at the end face, not total power. At the same 30 W, a 1000 μm core and a 200 μm core differ by 25 times in power density. The first may be entirely fine and the second burns in seconds. For holmium lithotripsy and industrial marking, an end cap is effectively standard.
No single fixed part number table covers every SMA905 requirement. The specification is a combination of the five parameters below. Specify all five and the model is determined:
| Parameter | Options | Effect |
|---|---|---|
| Ferrule bore | 126 / 140 / 230 / 440 / 600 / 1000 μm, custom bores available | Centering accuracy, coupling efficiency, must match fiber OD |
| Ferrule material | Ceramic (zirconia) / stainless steel / copper alloy | Wear, temperature, cost; ceramic or copper for high power |
| End face form | Flat / spherical / end cap | Return loss, power handling |
| Housing material | Stainless steel / nickel plated brass / aluminium | Strength, corrosion, heat dissipation |
| Boot type | Standard crimp / armored / short / no boot | Tensile strength, clearance, ingress protection |
If you have your own part numbering system, we can build the cross reference to your rules so the two sides do not drift apart and cause wrong part orders.
| Item | Typical Value |
|---|---|
| Thread | 5/16-24 UNF |
| Ferrule outside diameter | 3.17 mm (1/8 inch) common, also available in 2.5 mm |
| Ferrule bore | 126 μm to 1000 μm, selected against fiber OD |
| Insertion loss | Typically 0.5-1.5 dB (air gap design, higher than PC types) |
| Return loss | Typically about -20 dB (structural, not a defect) |
| Operating temperature | -40 to +150C depending on ferrule and housing material |
| Mating cycles | Housing and ferrule reusable long term; the fiber must be re-terminated |
| Tensile strength | Depends on crimp quality, typically 50 N or more |
Values above are common industry figures. Actual performance follows the datasheet and lot sampling data. For volume purchasing, specify acceptance on a distribution rather than a single sample figure.
| Application | Typical Configuration | Key Requirement |
|---|---|---|
| Medical laser (holmium lithotripsy, Nd:YAG) | 600 / 1000 μm silica, ceramic ferrule, end cap | End face survival, sterilizability, low loss |
| Aesthetic laser (808 / 1064 nm) | 400-600 μm with end cap | Power stability, matching the equipment interface |
| Spectroscopy and detection | 200-600 μm multimode, flat polish | Coupling efficiency, repeatability |
| Fiber sensing | 125 μm or large core, SMA906 | Centering accuracy, long term stability |
| High power industrial delivery | Large core silica, copper ferrule, end cap | Heat dissipation, burn resistance, tensile strength |
| Fiber bundles and imaging bundles | SMA906 with custom bundle diameter | Centering, packing fraction, broken fiber rate |



| Item | Notes | Page |
|---|---|---|
| Holmium laser fiber | Low OH silica for 2100 nm | View |
| Aesthetic laser fiber | 532-2940 nm wavelength selection | View |
| Large core silica fiber | From 200/230 μm | View |
| ST connectors | Bayonet, industrial and sensing | View |
| Image fiber and bundles | Coherent and incoherent | View |
905 refers to the thread specification 5/16-24 UNF: 0.3125 inch outside diameter with 24 threads per inch, unified fine thread. It is the interface basis of the SMA family and says nothing about the fiber. So a request for SMA905 only fixes the thread. Ferrule bore, ferrule material and end face form are all still open, and those three determine whether it works.
SMA905 is the basic type: the fiber passes directly into the ferrule bore and is bonded in place. SMA906 adds a shoulder ring that centers the fiber precisely on the ferrule axis, which is more stable for multimode large core. Simple rule: small core, short reach and cost sensitive use SMA905; large core, multimode and repeatability critical use SMA906. The threads are identical so both mate with the same receptacle, but the internal centering differs.
Because SMA905 uses an air gap: there is a small gap between the two ferrule end faces rather than physical contact. The glass to air interface produces Fresnel reflection, giving return loss around -20 dB, while physical contact reaches -40 dB or better. This is structural, not a quality defect. Applications sensitive to return loss such as narrow linewidth lasers and interferometry should not use SMA905. High power applications need exactly this air gap to avoid burning the end face.
The bore must match the fiber outside diameter. This is the most common purchasing error with SMA905. Common bores are 126 micron for 125 micron cladding, plus 230, 440, 600 and 1000 micron. If the bore is too large the fiber sits off center, coupling efficiency drops and becomes unstable. If the bore is too small the fiber will not enter, and forcing it chips the end. Always state both the fiber outside diameter and the coating diameter when requesting a quote.
Three. Flat polish is most common, simple and low cost, suitable for multimode and large core. Spherical polish is used where lower return loss is wanted, but since SMA905 already has an air gap the benefit is limited. An end cap is a coreless silica rod fusion spliced to the fiber end, spreading the beam and reducing power density. It is used for high power laser and medical lithotripsy and is the most effective way to prevent end face damage.
Once power density exceeds the silica damage threshold, yes. The criterion is power density at the end face, not total power. At the same 30 W, a 1000 micron core and a 200 micron core differ by 25 times in power density. A small core carrying high power will burn quickly. An end cap expands the beam into the coreless rod and reduces power density by one to two orders of magnitude. For holmium lithotripsy and industrial marking, an end cap is effectively standard.
The housing, nut and ferrule can be reused; the fiber cannot. The ferrule is a replaceable part and the fiber is bonded into the bore with adhesive, so changing the fiber means disassembly and re-curing. In practice field maintenance stocks finished patch cords rather than terminating on site. Before reusing a ferrule, check the bore wall for residual adhesive, which prevents a new fiber from seating fully.
SMA905 is a configurable product determined by five parameters: ferrule bore, ferrule material, end face form, housing material and boot type. No single fixed part number table covers every requirement. Provide these five and we can define the model. If you have your own part numbering system we can build the cross reference to your rules so the two sides do not drift apart and cause wrong part orders.
Tell us the fiber core, cladding diameter, coating diameter, delivered power and equipment interface. We will propose the ferrule bore, material and end face form. If you have a part numbering system we can map to it.
Get Quote